FM Transmitter Measurement Report
Created: 2023-06-04 11-08-19
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
89.90 MHz |
5/5, 79 dBuV |
FREQ 3 |
Pilot |
RDS |
Phase
Difference |
6.8 kHz |
4.2 kHz |
3 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
13 kHz |
72 kHz |
17184 |
0,0349 |
|
Modulation Power
Limit |
Measuring
Tolerance |
8,0 dBr |
0,0 dBr |
MIN |
AVE |
MAX |
% above
8,0 dBr |
7,4 dBr |
8,05 dBr |
8,5 dBr |
54,5 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
" FREQ 3 " |
F536 |
0 (No PTY) |
1 |
0 |
1 |
7 |
11:08, 4.06.2023 |
RT |
"Loïs Andrea -> Insomnie " |
AF |
EON |
89.9, 99.0 MHz |
- |
|
|